Now included with ISY Portal - Requires firmware and UI versions 4.4.3+
When you again have access to ISY, change the network setting to automatic (DHCP). When your new router is subsequently installed, you will be able to access ISY and edit its IP address back to a static one recognized by the new router.
- Of course with the help of driver easy pro software, you don’t need to bother looking and downloading drivers from the internet which is not quite safe. In addition to downloading all types of drivers, Driver Easy Pro Full Version also helps us to always update the laptop or PC hardware driver to the latest version.
- The ISY is a nice device and will play the role of the master controller in an Insteon setup, Control4 will replace the ISY and will do the same and WAY more than the ISY. It will communicate directly to the PLM like the ISY does so response time will be greatly optimized.
- ELK Products Inc 3266 US Hwy 70. Connelly Springs, NC 28612 (800) 797-9355.
Drivers Isy Network & Wireless Cards Compatible
- 3Network Resources
- 4Web Server Module
- 4.2Dynamic/Custom Page Creation
Install
If you do not haveISY Portal(Requires firmware and UI versions 4.4.3+), please go to Admin Console | Help | Purchase Modules and purchase Network Module.
After installation the Configure panel will contain a Networking tab. The Networking tab will have three sub-tabs.
A Network command will be added to the Action menu in your Programs.
Wake On LAN
To configure Wake On LAN settings:
- Click on the Add button at the bottom of the frame.
- Double-click the Name to Rename the computer to something meaningful.
- Double-click the MAC Address to enter the proper address (use dashes '-' between the byte sets: 00-11-3D-70-A6-64)
- Single-click the Broadcast column to open the Resource Editor.
- Enter the IP address of the computer.
- Enter the Subnet of the router.
- Click Calculate to determine the Broadcast address.
- Double-click the Password if it is necessary.
- Be sure to Press Save.
Now you can use WOL in your Programs!
Network Resources
Network Resources allows the ISY to call other systems using HTTP/HTTPS/TCP/UDP/Multicast.Please note that you need PRO features for Advanced HTTPS/Cipher suites functionality
Available HTTP/HTTPS commands include GET/POST/CONNECT/DELETE/HEAD/PUT/TRACE.
POST and PUT allow the use of URL-ENCODED, RAW TEXT, and BINARY modes.
Please see this page for some examples of devices you can control using this module:
Network Resources (Examples & Downloads)
Substitution Variables
Geo Fence and Integration with Tasker
You'll also find downloadable export files - save time and trouble by importing pre-configured Network Resources right into your ISY!
From version 4.3.3 you can include | substitutions. If you include substitutions in the URL then you cannot use the 'Encode URL' option - if you select this then the substitution will not occur.
Web Server Module
This module allows you to host your own web site directly on the ISY, making it accessible from any internet-capable device (PC, Mac, cell phone, PDA, etc.)
Usage
Once installed, you can access the Web Server module by clicking the Configuration tab in the ISY's Administrative Console, selecting the Networking tab, and then clicking the Web Server tab.
Browse through files and folders on your PC using the left-hand portion of the screen, while the right-hand portion allows you to browse through the ISY's folders.
Drag and drop files from the left hand side of the screen to the right side's USERWEB folder to load files onto your ISY. Once copied to the ISY, files can be viewed using a web browser. For example, load a photo called 'family.jpg' onto your ISY and you can view the photo in Internet Explorer using the following URL:
http://ipaddress/USER/WEB/family.jpg
(where 'ipaddress' is your ISY's internal or external IP address)
Drivers Isy Network & Wireless Cards Customer Service
To set a loaded file as your ISY's home page, simply right-click the file and choose 'Set as Homepage'. This page will come up automatically when visiting your ISY's main page (http://ipaddress). You can also right-click a file to Rename or Remove it from the ISY. Finally, right-click a file and click Open to preview it within your default web browser. To revert to the default ISY home page, simply click the 'Use Default' button on the left-hand side of the screen.
Feel free to create and load your own custom HTML files to personalize your ISY's main page. You may want to add links to other web-based devices in your home, such as webcams. You can also customize the look of the home page with personalized colors, fonts and graphics. Or, load up your business, personal or family web site onto the ISY - the possibilities are endless.
Note: Web pages are not saved in an ISY backup. They will have to be reloaded after a Factory Reset.
Dynamic/Custom Page Creation
Starting with 4.0.2 firmware, we added an enhancement to the Networking module that allows you to update files in /user/web when sending a notification from programs. This allows you to make custom HTML files, XML files, or do some custom logging to that directory.
The interface requires the direct use of keywords, although at some point we may make a more user friendly version in the GUI. When creating a custom notification, do the following:
- Start the subject with @webpage:
- Optionally add @append: or @delete:; nothing specified means create or overwrite the file
- Supply the relative file path to /USER/WEB, e.g. specify myDir/hi.htm for /user/web/myDir/hi.htm
- You may update multiple files by supplying multiple @webpage:... entries separated by a space
- Add an actual e-mail subject if this is to be e-mailed as well
NOTE: You can fully use substitution variables to create the subject, allowing file names based on a variable for example.NOTE: File names are limited to the 8.3 format
Here are some exmaples:
Send notification with subject 'My Status'
- No file is created
Subject: My Status
Create File and Send Notification
- Creates the file /user/web/mydir/status.htm whose content is the body of this notification
- Sends an e-mail notification with subject 'My Status'
Subject: @webpage:myDir/status.htm My Status
Create File Only
- Creates the file /user/web/mydir/status.htm whose content is the body of this notification (no e-mail notification sent out)
Subject: @webpage:myDir/status.htm
Append to an Existing File
- Appends body of this message to file /user/web/mydir/status.htm
Subject: @webpage:@append:/mydir/status.htm
Create File Named Based on Variable Value
- Creates file with name based on the value of a variable (e.g. if the variable=24, then file is /user/web/mydir/file24.txt)
Subject: @webpage:/mydir/file${var.1.1}.txt
Delete File
- Deletes a file
Subject: @webpage:@delete:/mydir/status.htm
Multi Operations
- Create file /user/web/mydir/status.htm whose content is the body of this notification
- Append the content to /user/web/mydir/log.htm
Subject: @webpage:mydir/status.htm @webpage:@append:mydir/log.htm
Related Pages
ISY-99i Series INSTEON:
Drivers Isy Network & Wireless Cards Online
Setup And Control for Insteon Network- Desk Top Interface Provides Linking And Setup For Inteon Devices
- Support for KeypadLinc and RemoteLinc - Linking And Button Settings
- Computer Groups/Scenes Setup And Control
- Timer And Logic Functions
- 32 Bit and 64 Bit Versions
- Windows And Linux Versions
- Tested And Capable Of Running On Inexpensive Tablet Or Laptop For Months Without Interuption
This makes it easier to configure and pair Controller with Responders. Software Requirements:
- Available for version Windows 7 and later
- Linux Debian Version.
Drivers Isy Network & Wireless Cards App
Hardware Requirements:- Insteon Powerline Modem (PLM), Serial or USB - 2413U, 2413S, 2412U, 2412S, or 2448A7
The USB Insteon PowerLinc Modem is a USB-based interface that allows PC- and hardware-based automation controllers to control and monitor Insteon-compatible lights, appliances, heating/air conditioning systems and alarm systems directly via the Insteon network. - Why Not The HUB? The HUB does not provide any adequate interface for software setup and control beyond what the HUB APP can already do...
LinkNet For 32 bit and 64 bit Windows
LinkNet-setup.msi ~ 6.2MB - Windows Desktop And Web Data Server Edition
LinkNet For 32 bit and 64 bit Linux Debian
linknet_3.8-4.deb ~ 5MB - Linux Desktop And Web Data Server Edition
Updated better support for Version 3 devices.
User interface updates to make this easier to use.
Always adding device specific settings views; Most recent for motion sensor and chime/siren.
Always improving device network setup, control and motitor technology.
Microsoft Edge - The web server uses javascript to build and update pages, Firefox and Chrome display fine, Edge No.
The Microsoft Windows Installer (MSI) is the application installation and configuration service for Windows.
The installer uses a standard wizard interface with reasonable defaults.
Right-click the MSI file and select Install. See Get Started
After installation the installer also shows an update and un-install feature for later use if needed.
Version updates - Windows Installer does not remove previous version configuration files.
If an update requires deletion of previous configuration files.
Example configuration files Location:C:UsersusernameAppDataLocalVirtualStoreProgram Files (x86)appname
Right click on .deb file
Choose Open with gdebi package installer
OR,
In Terminal: sudo gdebi linknet_3.5-0.deb
gdebi is a lightweight GUI application with the sole purpose of installing deb packages.
It identifies the dependencies and tries to install these along with the .deb files.
If you don't have gdebi installed already, install it using: sudo apt install gdebi-core
Enable Serial/USB Port For Powerline Modem
The Powerline Modem must be plugged in to continue (1).
Open Terminal
mp@lap:~$ ls -l /dev/ttyUSB0
That should show what group owns ttyUSB0, it's probably the dialout group
$ crw-rw---T 1 root dialout 188, 0 Feb 12 12:01 /dev/ttyUSB0
* User needs to be added: [username-to-add] without the brackets
sudo adduser [username-to-add] dialout
Reboot for dialout changes to take affect.
ls: cannot access '/dev/ttyUSB0': No such file or directory
NEED TO PLUG IN POWERLINE MODEM
mp@lap:~$ ls -l /dev/ttyUSB0
crw-rw---- 1 root dialout 188, 0 Jul 22 22:27 /dev/ttyUSB0
mp@lap:~$ sudo adduser mp dialout
[sudo] password for mp:
Adding user 'mp' to group 'dialout' ...
Done.
mp@lap:~$
* Reboot For Changes To Take Affect.
More Info:
https://forums.linuxmint.com/viewtopic.php?t=135914
USB DRIVERS FOR INSTEON POWERLINE MODEM
Recent Windows and Linux OS Versions Automatically Install And Support FTDI USB Drivers - (pertains to USB PLM)
Older OS versions may require manual download and install for FTDI USB drivers
- Latest USB drivers from manufacturerhttps://www.ftdichip.com/Drivers/VCP.htm
Windows
AppDataFolder - Location varies
Example: C:UserszwebsterAppDataLocalVirtualStoreProgram Files (x86)insteonsoftwareLinkNet
Linux
/var/lib/linknet
Datafile Filenames
linknetdisco.dat
linknetoptions.dat
linknetplm.dat
linknetevents.dat